Type K thermocouple for VITA Vacumat and Programat porcelain furnaces
Aftermarket type K (NiCr–NiAl) sensor replacement compatible with VITA Vacumat and Programat series porcelain furnaces. Fast response and slim sheath, supplied with the matching furnace-specific connector.
Description
This is an aftermarket replacement thermocouple produced by an independent manufacturer. It is compatible with VITA Vacumat and Ivoclar Vivadent Programat series porcelain furnaces but is not manufactured by, authorised by or endorsed by VITA or Ivoclar Vivadent. VITA, Vacumat, Ivoclar Vivadent and Programat are registered trademarks of their respective owners, referenced solely to indicate compatibility.
Porcelain programs live in the narrow band between 750 °C and 1000 °C where an aged or drifting thermocouple does the most damage. This replacement uses a fine-wire NiCr–NiAl pair in a slim ceramic sheath for fast response in vacuum firings, with the connector geometry manufactured to match the target furnace family.
Key features
- Fine-wire type K element for fast response in short firing cycles
- Slim ceramic sheath fits standard measurement openings
- Original-style connector included — plug-and-play
- Stable within ±2 °C across the porcelain firing range
- Aftermarket part — compatible, not a VITA or Ivoclar product
Technical specifications
| Sensor type | Type K (NiCr–NiAl) |
|---|---|
| Max. temperature | 1200 °C |
| Tolerance | Class 1, ±1.5 °C |
| Sheath diameter | 3 mm / 6 mm (model-dependent) |
| Compatibility note | Aftermarket — not a VITA or Ivoclar original part |
Furnace compatibility
This part is a dimensionally and functionally equivalent replacement for the following furnace families:
- Compatible with VITA Vacumat 400t / 6000 MP — VITA is a trademark of its owner; this is an aftermarket sensor, not affiliated with or endorsed by VITA
- Compatible with Ivoclar Vivadent Programat P300 / P500 — Ivoclar Vivadent and Programat are trademarks of their owners; this is an aftermarket sensor, not affiliated with or endorsed by Ivoclar Vivadent
Frequently asked questions
How often should a porcelain furnace thermocouple be replaced?
In active labs, check calibration every 6–12 months. Replace immediately if results become inconsistent or a reference thermometer shows more than ±5 °C deviation at firing temperature.
Aftermarket replacement part. Not an original equipment manufacturer (OEM) product. This is an aftermarket replacement part produced by an independent manufacturer. It is not an original product of, manufactured by, authorised by, sponsored by or endorsed by any furnace brand referenced on this page. All brand names and model designations are trademarks of their respective owners and are used solely to indicate compatibility.
EU Responsible Person: Nickolas Constantine, Bulevar Džordža Vašingtona 12/3, 81000 Podgorica, Montenegro — contact via the inquiry form. Information on the economic operator and product safety is provided in the legal notice pursuant to Regulation (EU) 2023/988 (GPSR).